First, check these
- Check which side of the glass is fogged: customer side (outside) or product side (inside).
- Look for a ceiling fan, pedestal fan or AC outlet blowing onto the case. Moving air disrupts the case's air pattern.
- Check rear doors or sliding panels are closed and staff are not leaving them open during service.
- Check product is not stacked above the load line or pressed against the glass, blocking the air circulation.
- Check that any glass heater or anti-mist switch is on.
- Check the case setpoint has not been lowered. Colder glass fogs more easily without making the food any safer.
Likely causes
1. Room humidity beyond design
You can check thisSigns: Outside fogging on humid days or near the entrance; clears in drier weather or when the AC runs.
Fix: Keep the shop door closed where AC is used, move the case away from the entrance, and control room humidity. Wipe with a dry, lint-free cloth.
2. Fan or AC draught on the case
You can check thisSigns: Fog in a patch facing a fan or AC outlet; cold air spilling from the case.
Fix: Redirect fans and AC louvres away from the case, or relocate the case.
3. Rear doors left open
You can check thisSigns: Inside fogging during service; warm air from the back counter entering the case.
Fix: Train staff to close rear doors after each serve and use night covers or blinds after hours.
4. Overloading or warm product
You can check thisSigns: Trays above the load line, fresh-baked or still-warm items placed in the case, steam visible on loading.
Fix: Load below the marked line and allow baked or cooked items to cool before display.
5. Glass heater or anti-mist feature failed
Technician jobSigns: Glass much colder than usual; fog appeared suddenly though conditions have not changed.
Fix: A technician should test the heater circuit and controls.
6. Iced evaporator or fan fault
Technician jobSigns: Weak airflow inside, rising product temperature as well as fogging.
Fix: A technician should check the defrost system and evaporator fans.
When to call a technician
Call a technician if fogging continues after you have dealt with draughts, rear doors and loading, if the glass heater seems dead, or if product temperatures are also rising. Fog between double-glazing panes means a failed glass seal and needs a glass replacement.
Isolate power before cleaning glass heaters, light rails or the inside of the case. Use cleaners suitable for coated glass and avoid spraying liquid onto electrical parts. Hydrocarbon refrigerant (R290 or R600a) units need trained technicians for any refrigeration work.