First, check these
- Switch the unit off at the socket and wait until the supply looks stable, for example lights steady and other appliances working normally.
- Check the MCB or RCCB on the circuit and any stabiliser or voltage protector. Many cut out on purpose and need a reset or a waiting period.
- Smell and look around the plug, socket, stabiliser and machine compartment for burning, scorch marks or melted plastic. If you find any, keep it off.
- Switch on once. Watch whether the display lights, the fans run and the compressor starts after any delay.
- If it runs, check the temperature recovers over the next hour or two.
Likely causes
1. Protection device tripped
You can check thisSigns: Stabiliser or voltage protector shows a fault light or no output; MCB in the off position.
Fix: Reset as per the device instructions once the supply is stable. If it trips again immediately, stop and call an electrician or technician.
2. Controller or display damaged
Technician jobSigns: Display dead or showing random characters while the socket has power; fans and compressor do not respond.
Fix: A technician must test and replace the controller or its power supply.
3. Start relay, PTC or capacitor damaged
Technician jobSigns: Compressor clicks and hums but will not run; overload cycling every few minutes.
Fix: A technician replaces the starting components and checks the compressor. Do not let it keep clicking.
4. Fan motor or LED driver burnt
Technician jobSigns: One function dead after the event, such as no condenser fan, no interior fan or no lights, while the rest works.
Fix: A technician should replace the failed part. If the condenser fan is dead, keep the compressor off to prevent overheating.
5. Compressor winding damage
Technician jobSigns: MCB or RCCB trips whenever the compressor tries to start; burning smell from the compressor area.
Fix: A technician confirms with electrical tests. Compressor replacement is a sealed-system job.
6. Loose or damaged supply wiring
Technician jobSigns: Socket or plug warm, discoloured or loose; problem comes and goes when the cord is moved.
Fix: Stop using the socket and have an electrician repair the wiring. A poor connection causes its own voltage drop.
When to call a technician
Call a technician if the unit does not run normally after one clean restart, if anything smells burnt, if protection trips again, or if only part of the unit works. Ask an electrician to check earthing and supply quality if fluctuations are frequent. Protect the replacement: a voltage protector with a restart time delay, or a stabiliser sized for the compressor's starting load, costs far less than a compressor.
Do not touch scorched plugs, sockets or wiring; isolate at the MCB first. Never bypass a stabiliser or protector to get a unit running. Starting components can hold a charge, so only technicians should open terminal boxes, and hydrocarbon (R290 or R600a) systems need trained technicians.